Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 12.266
Filtrar
1.
Clin Cardiol ; 47(4): e24266, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38587231

RESUMO

BACKGROUND: Electrocardiography (ECG) and 24 hours Holter monitoring (24 h-Holter) provided valuable information for premature ventricular and supraventricular contractions (PVC and PSVC). Currently, artificial intelligence (AI) based 2 hours single-lead Holter (2 h-Holter) monitoring may provide an improved strategy for PSVC/PVC diagnosis. HYPOTHESIS: AI combined with single-lead Holter monitoring improves PSVC/PVC detection. METHODS: In total, 170 patients were enrolled between August 2022 and 2023. All patients wore both devices simultaneously; then, we compared diagnostic efficiency, including the sensitivity/specificity/positive predictive-value (PPV) and negative predictive-value (NPV) in detecting PSVC/PVC by 24 h-Holter and 2 h-Holter. RESULTS: The PPV and NPV in patients underwent 2 h-Holter were 76.00%/87.50% and 96.35%/98.55, respectively, and the sensitivity and specificity were 79.17%/91.30%, and 95.65%/97.84% in PSVC/PVC detection compared with 24 h-Holter. The areas under the ROC curves (AUCs) for PSVC and PVC were 0.885 and 0.741, respectively (p < .0001). CONCLUSIONS: The potential advantages of the 2 h-Holter were shortened wearing period, improved convenience, and excellent consistency of diagnosis.


Assuntos
Eletrocardiografia Ambulatorial , Complexos Ventriculares Prematuros , Humanos , Inteligência Artificial , Complexos Ventriculares Prematuros/diagnóstico , Eletrocardiografia , Valor Preditivo dos Testes
2.
Comput Methods Programs Biomed ; 249: 108157, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38582037

RESUMO

BACKGROUND AND OBJECTIVE: T-wave alternans (TWA) is a fluctuation in the repolarization morphology of the ECG. It is associated with cardiac instability and sudden cardiac death risk. Diverse methods have been proposed for TWA analysis. However, TWA detection in ambulatory settings remains a challenge due to the absence of standardized evaluation metrics and detection thresholds. METHODS: In this work we use traditional TWA analysis signal processing-based methods for feature extraction, and two machine learning (ML) methods, namely, K-nearest-neighbor (KNN) and random forest (RF), for TWA detection, addressing hyper-parameter tuning and feature selection. The final goal is the detection in ambulatory recordings of short, non-sustained and sparse TWA events. RESULTS: We train ML methods to detect a wide variety of alternant voltage from 20 to 100 µV, i.e., ranging from non-visible micro-alternans to TWA of higher amplitudes, to recognize a wide range in concordance to risk stratification. In classification, RF outperforms significantly the recall in comparison with the signal processing methods, at the expense of a small lost in precision. Despite ambulatory detection stands for an imbalanced category context, the trained ML systems always outperform signal processing methods. CONCLUSIONS: We propose a comprehensive integration of multiple variables inspired by TWA signal processing methods to fed learning-based methods. ML models consistently outperform the best signal processing methods, yielding superior recall scores.


Assuntos
Arritmias Cardíacas , Eletrocardiografia Ambulatorial , Humanos , Eletrocardiografia Ambulatorial/métodos , Frequência Cardíaca , Arritmias Cardíacas/diagnóstico , Morte Súbita Cardíaca , Processamento de Sinais Assistido por Computador , Eletrocardiografia/métodos
3.
BMC Neurol ; 24(1): 120, 2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38605308

RESUMO

BACKGROUND: Atrial fibrillation (AF) screening after ischemic stroke or transient ischemic attack (TIA) is given high priority in clinical guidelines. However, patient selection, electrocardiogram (ECG) modality and screening duration remains undecided and current recommendations vary. METHODS: The aim of this study was to investigate the clinical practice of AF screening after ischemic stroke or TIA at Swedish stroke units. In collaboration with the stakeholders of the Swedish Stroke Register (Riksstroke) a digital survey was drafted, then tested and revised by three stroke consultants. The survey consisted of 17 multiple choice/ free text questions and was sent by e-mail to the medical directors at all stroke units in Sweden. RESULTS: All 72 stroke units in Sweden responded to the survey. Most stroke units reported that ≥ 75% of ischemic stroke (69/72 stroke units) or TIA patients (67/72 stroke units), without previously known AF, were screened for AF. Inpatient telemetry ECG was the method of first-choice in 81% of the units, but 7% reported lack of access. A variety of standard monitoring durations were used for inpatient telemetry ECG. The second most common choice was Holter ECG (17%), also with considerable variations in monitoring duration. Other AF screening modalities were used as a first-choice method (handheld and patch ECG) but less frequently. CONCLUSIONS: Clinical practice for AF screening after ischemic stroke or TIA differed between Swedish stroke units, both in choice of AF screening methods as well as in monitoring durations. There is an urgent need for evidence and evidence-based recommendations in this field. TRIAL REGISTRATION: Not applicable.


Assuntos
Fibrilação Atrial , Ataque Isquêmico Transitório , AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Ataque Isquêmico Transitório/complicações , Ataque Isquêmico Transitório/diagnóstico , Ataque Isquêmico Transitório/epidemiologia , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Suécia/epidemiologia , Eletrocardiografia Ambulatorial , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia
4.
Sci Rep ; 14(1): 8969, 2024 04 18.
Artigo em Inglês | MEDLINE | ID: mdl-38637619

RESUMO

Duchenne muscular dystrophy (DMD) patients exhibit a late left ventricular systolic dysfunction preceded by an occult phase, during which myocardial fibrosis progresses and some early functional impairments can be detected. These latter include electrocardiographic (ECG) and heart rate variability (HRV) abnormalities. This longitudinal study aimed at describing the sequence of ECG and HRV abnormalities, using Holter ECG in the GRMD (Golden retriever muscular dystrophy) dog model, known to develop a DMD-like disease, including cardiomyopathy. Most of the known ECG abnormalities described in DMD patients were also found in GRMD dogs, including increased heart rate, prolonged QT and shortened PR intervals, ventricular arrhythmias, and several of them could be detected months before the decrease of fractional shortening. The HRV was impaired like in DMD patients, one of the earliest evidenced abnormalities being a decrease in the very low frequency (VLF) component of the power spectrum. This decrease was correlated with the further reduction of fractional shortening. Such decreased VLF probably reflects impaired autonomic function and abnormal vasomotor tone. This study provides new insights into the knowledge of the GRMD dog model and DMD cardiomyopathy and emphasizes the interest to monitor the VLF power in DMD patients, still unexplored in this disease, whilst it is highly predictive of deleterious clinical events in many other pathological conditions.


Assuntos
Cardiomiopatias , Distrofia Muscular de Duchenne , Humanos , Cães , Animais , Distrofia Muscular de Duchenne/patologia , Frequência Cardíaca , Eletrocardiografia Ambulatorial , Estudos Longitudinais
6.
Europace ; 26(3)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38466042

RESUMO

AIMS: Premature ventricular contractions (PVC) and non-sustained ventricular tachycardia (NSVT) are commonly observed in light chain cardiac amyloidosis (AL-CA), but their association with prognosis is still unclear. We aimed to evaluate the prognostic value of PVCs and NSVT in patients with moderate-to-advanced AL-CA. METHODS AND RESULTS: We retrospectively included patients with AL-CA at modified 2004 Mayo stages II-IIIb between February 2014 and December 2020. Twenty-four-hour Holter recordings were assessed on admission. The outcomes included (i) new onset of adverse ventricular arrhythmia (VA) or sudden cardiac death (SCD) and (ii) cardiac death during follow-up. Of the 143 patients studied (60.41 ± 11.06 years, male 64.34%), 132 (92.31%) had presence of PVC, and 50 (34.97%) had NSVT on Holter. Twelve (8.4%) patients died in hospital and 131 patients were followed up (median 24.4 months), among whom 71 patients had cardiac death, and 15 underwent adverse VA/SCD. NSVT [hazard ratio (HR): 13.57, 95% confidence interval (CI): 3.06-60.18, P < 0.001], log-transformed PVC counts (HR: 1.46, 95%CI: 1.15-1.86, P = 0.002) and PVC burden (HR: 1.43 95%CI:1.14-1.80, P = 0.002) were predictive of new onset of adverse VA/SCD. The highest tertile of PVC counts (HR: 2.33, 95%CI: 1.27-4.28, P = 0.006) and PVC burden (HR: 2.58, 95%CI: 1.42-4.69, P = 0.002), rather than NSVT (HR: 1.16, 95%CI: 0.67-1.98, P = 0.603), was associated with cardiac death. Higher PVC counts/burden provided incremental value on modified 2004 Mayo stage in predicting cardiac death, with C index increasing from 0.681 to 0.712 and 0.717, respectively (P values <0.05). CONCLUSION: PVC count, burden, and NSVT significantly correlated with adverse VA/SCD during follow-up in patients with AL-CA. Higher PVC counts/burdens added incremental value for predicting cardiac death.


Assuntos
Taquicardia Ventricular , Complexos Ventriculares Prematuros , Humanos , Masculino , Prognóstico , Estudos Retrospectivos , Eletrocardiografia Ambulatorial , Morte Súbita Cardíaca
7.
J Am Heart Assoc ; 13(7): e032740, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38533972

RESUMO

BACKGROUND: Autonomic function can be measured noninvasively using heart rate variability (HRV), which indexes overall sympathovagal balance. Deceleration capacity (DC) of heart rate is a more specific metric of vagal modulation. Higher values of these measures have been associated with reduced mortality risk primarily in patients with cardiovascular disease, but their significance in community samples is less clear. METHODS AND RESULTS: This prospective twin study followed 501 members from the VET (Vietnam Era Twin) registry. At baseline, frequency domain HRV and DC were measured from 24-hour Holter ECGs. During an average 12-year follow-up, all-cause death was assessed via the National Death Index. Multivariable Cox frailty models with random effect for twin pair were used to examine the hazard ratios of death per 1-SD increase in log-transformed autonomic metrics. Both in the overall sample and comparing twins within pairs, higher values of low-frequency HRV and DC were significantly associated with lower hazards of all-cause death. In within-pair analysis, after adjusting for baseline factors, there was a 22% and 27% lower hazard of death per 1-SD increment in low-frequency HRV and DC, respectively. Higher low-frequency HRV and DC, measured during both daytime and nighttime, were associated with decreased hazard of death, but daytime measures showed numerically stronger associations. Results did not substantially vary by zygosity. CONCLUSIONS: Autonomic inflexibility, and especially vagal withdrawal, are important mechanistic pathways of general mortality risk, independent of familial and genetic factors.


Assuntos
Veteranos , Humanos , Bradicardia , Desaceleração , Eletrocardiografia Ambulatorial , Frequência Cardíaca/fisiologia , Estudos Prospectivos
8.
J Med Internet Res ; 26: e46098, 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38512332

RESUMO

BACKGROUND: Wearable electrocardiogram (ECG) monitoring devices are used worldwide. However, data on the diagnostic yield of an adhesive single-lead ECG patch (SEP) to detect premature ventricular complex (PVC) and the optimal duration of wearing an SEP for PVC burden assessment are limited. OBJECTIVE: We aimed to validate the diagnostic yield of an SEP (mobiCARE MC-100, Seers Technology) for PVC detection and evaluate the PVC burden variation recorded by the SEP over a 3-day monitoring period. METHODS: This is a prospective study of patients with documented PVC on a 12-lead ECG. Patients underwent simultaneous ECG monitoring with the 24-hour Holter monitor and SEP on the first day. On the subsequent second and third days, ECG monitoring was continued using only SEP, and a 3-day extended monitoring was completed. The diagnostic yield of SEP for PVC detection was evaluated by comparison with the results obtained on the first day of Holter monitoring. The PVC burden monitored by SEP for 3 days was used to assess the daily and 6-hour PVC burden variations. The number of patients additionally identified to reach PVC thresholds of 10%, 15%, and 20% during the 3-day extended monitoring by SEP and the clinical factors associated with the higher PVC burden variations were explored. RESULTS: The recruited data of 134 monitored patients (mean age, 54.6 years; males, 45/134, 33.6%) were analyzed. The median daily PVC burden of these patients was 2.4% (IQR 0.2%-10.9%), as measured by the Holter monitor, and 3.3% (IQR 0.3%-11.7%), as measured in the 3-day monitoring by SEP. The daily PVC burden detected on the first day of SEP was in agreement with that of the Holter monitor: the mean difference was -0.07%, with 95% limits of agreement of -1.44% to 1.30%. A higher PVC burden on the first day was correlated with a higher daily (R2=0.34) and 6-hour burden variation (R2=0.48). Three-day monitoring by SEP identified 29% (12/42), 18% (10/56), and 7% (4/60) more patients reaching 10%, 15%, and 20% of daily PVC burden, respectively. Younger age was additionally associated with the identification of clinically significant PVC burden during the extended monitoring period (P=.02). CONCLUSIONS: We found that the mobiCARE MC-100 SEP accurately detects PVC with comparable diagnostic yield to the 24-hour Holter monitor. Performing 3-day PVC monitoring with SEP, especially among younger patients, may offer a pragmatic alternative for identifying more individuals exceeding the clinically significant PVC burden threshold.


Assuntos
Complexos Ventriculares Prematuros , Masculino , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Complexos Ventriculares Prematuros/diagnóstico , Eletrocardiografia , Eletrocardiografia Ambulatorial , Tecnologia
9.
Int J Cardiol ; 404: 131930, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38447764

RESUMO

BACKGROUND: Atrial fibrillation (AF) is one of the most common complications after cardiac surgery. New-onset post-operative AF may signal an elevated risk of AF and associated outcomes in long-term follow-up. We aimed to estimate the rate of AF recurrence as detected by an implantable loop recorder (ILR) in patients experiencing post-operative AF within 30 days after cardiac surgery. METHODS: We searched MEDLINE, Embase and Cochrane CENTRAL to April 2023 for studies of adults who did not have known AF, experienced new-onset AF within 30 days of cardiac surgery and received an ILR. We pooled individual participant data on timing of AF recurrence using a random-effects model with a frailty model applied to a Cox proportional hazard analysis. RESULTS: From 8671 citations, 8 single-centre prospective cohort studies met eligibility criteria. Data were available from 185 participants in 7 studies, with a median follow-up of 1.7 (IQR: 1.3-2.8) years. All included studies were at a low risk of bias. Pooled AF recurrence rates following 30 post-operative days were 17.8% (95% CI 11.9%-23.2%) at 3 months, 24.4% (17.7%-30.6%) at 6 months, 30.1% (22.8%-36.7%) at 12 months and 35.3% (27.6%-42.2%) at 18 months. CONCLUSIONS: In patients who experience new-onset post-operative AF after cardiac surgery, AF recurrence lasting at least 30 s occurs in approximately 1 in 3 in the first year after surgery. The optimal frequency and modality to use for monitoring for AF recurrence in this population remain uncertain.


Assuntos
Fibrilação Atrial , Procedimentos Cirúrgicos Cardíacos , Adulto , Humanos , Estudos Prospectivos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/etiologia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Próteses e Implantes , Fatores de Tempo , Eletrocardiografia Ambulatorial , Recidiva
10.
Stroke ; 55(4): 946-953, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38436115

RESUMO

BACKGROUND: Covert atrial fibrillation (AF) is a major cause of cryptogenic stroke. This study investigated whether a dose-dependent relationship exists between the frequency of premature atrial contractions (PACs) and AF detection in patients with cryptogenic stroke using an insertable cardiac monitor (ICM). METHODS: We enrolled consecutive patients with cryptogenic stroke who underwent ICM implantation between October 2016 and September 2020 at 8 stroke centers in Japan. Patients were divided into 3 groups according to the PAC count on 24-hour Holter ECG: ≤200 (group L), >200 to ≤500 (group M), and >500 (group H). We defined a high AF burden as above the median of the cumulative duration of AF episodes during the entire monitoring period. We evaluated the association of the frequency of PACs with AF detection using log-rank trend test and Cox proportional hazard model and with high AF burden using logistic regression model, adjusting for age, sex, CHADS2 score. RESULTS: Of 417 patients, we analyzed 381 patients with Holter ECG and ICM data. The median age was 70 (interquartile range, 59.5-76.5), 246 patients (65%) were males, and the median duration of ICM recording was 605 days (interquartile range, 397-827 days). The rate of new AF detected by ICM was higher in groups with more frequent PAC (15.5%/y in group L [n=277] versus 44.0%/y in group M [n=42] versus 71.4%/y in group H [n=62]; log-rank trend P<0.01). Compared with group L, the adjusted hazard ratios for AF detection in groups M and H were 2.11 (95% CI, 1.24-3.58) and 3.23 (95% CI, 2.07-5.04), respectively, and the adjusted odds ratio for high AF burden in groups M and H were 2.57 (95% CI, 1.14-5.74) and 4.25 (2.14-8.47), respectively. CONCLUSIONS: The frequency of PACs was dose-dependently associated with AF detection in patients with cryptogenic stroke.


Assuntos
Fibrilação Atrial , Complexos Atriais Prematuros , AVC Isquêmico , Acidente Vascular Cerebral , Masculino , Humanos , Idoso , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/complicações , Complexos Atriais Prematuros/diagnóstico , Complexos Atriais Prematuros/epidemiologia , Complexos Atriais Prematuros/complicações , Acidente Vascular Cerebral/diagnóstico , AVC Isquêmico/complicações , Eletrocardiografia Ambulatorial
11.
Eur J Pediatr ; 183(5): 2375-2382, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38446228

RESUMO

Although the mechanisms underlying the pathophysiology of long COVID condition are still debated, there is growing evidence that autonomic dysfunction may play a role in the long-term complications or persisting symptoms observed in a significant proportion of patients after SARS-CoV-2 infection. However, studies focused on autonomic dysfunction have primarily been conducted in adults, while autonomic function has not yet been investigated in pediatric subjects. In this study, for the first time, we assessed whether pediatric patients with long COVID present abnormalities in autonomic cardiac function. Fifty-six long COVID pediatric patients (mean age 10.3 ± 3.8 y) and 27 age-, sex-, and body surface area-matched healthy controls (mean age 10.4 ± 4.5y) underwent a standard 12-lead electrocardiography (ECG) and 24-h ECG Holter monitoring. Autonomic cardiac function was assessed by time-domain and frequency-domain heart rate variability parameters. A comprehensive echocardiographic study was also obtained by two-dimensional echocardiography and tissue Doppler imaging. Data analysis showed that pediatric patients with long COVID had significant changes in HRV variables compared to healthy controls: significantly lower r-MSSD (root mean square of successive RR interval differences, 47.4 ± 16.9 versus 60.4 ± 29.1, p = 0.02), significant higher values VLF (very low frequency, 2077.8 ± 1023.3 versus 494.3 ± 1015.5 ms, p = 0.000), LF (low frequency, 1340.3 ± 635.6 versus 354.6 ± 816.8 ms, p = 0.000), and HF (high frequency, 895.7 ± 575.8 versus 278.9 ± 616.7 ms, p = 0.000). No significant differences were observed between the two groups both in systolic and diastolic parameters by echocardiography.  Conclusion: These findings suggest that pediatric patients with long COVID have an imbalance of cardiac autonomic function toward a relative predominance of parasympathetic tone, as already reported in adult patients with long COVID. Further studies are needed to clarify the clinical significance of this autonomic dysfunction and demonstrate its role as a pathophysiological mechanism of long COVID, paving the way for effective therapeutic and preventive strategies. What is Known: • Long Covid in children has been described globally, but studies have mostly focused on collecting the temporal evolution of persisting symptoms. What is New: • Cardiac autonomic imbalance toward a relative predominance of parasympathetic tone is a mechanism underlying Long Covid in children, as also described in adults.


Assuntos
Sistema Nervoso Autônomo , COVID-19 , Eletrocardiografia Ambulatorial , Frequência Cardíaca , Humanos , Masculino , Feminino , Criança , Estudos de Casos e Controles , COVID-19/fisiopatologia , COVID-19/complicações , Adolescente , Frequência Cardíaca/fisiologia , Sistema Nervoso Autônomo/fisiopatologia , Síndrome Pós-COVID-19 Aguda , Coração/fisiopatologia , Eletrocardiografia , Ecocardiografia , SARS-CoV-2
12.
Pacing Clin Electrophysiol ; 47(5): 702-705, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38491749

RESUMO

BACKGROUND: Individuals with developmental and/or intellectual disabilities (I/DD) are at a greater risk for atrial fibrillation (AF), the most common type of cardiac arrhythmia. AF is associated with heart failure, stroke, poor mental health, and reduced quality of life. Management and treatment decisions are based on the ability to detect AF; however, noninvasive, remote cardiac monitoring may not be tolerated by individuals with I/DD. OBJECTIVE: To examine adherence to the placement of an ambulatory cardiac rhythm monitoring patch device by adult patients with I/DD. METHODS: Investigators extracted chart data from a consecutive series of adult patients (18 years+) who received the patch device as part of standard treatment at an adult health center between November 1, 2015 and October 31, 2019. RESULTS: A total of 95 patients were included in data analysis. Average age of subjects was 53.8 ± 13.9 years (range: 20.2-88.5); 66.7% were male. All subjects had intellectual disabilities as follows: mild, 37.9%; moderate, 29.5%; severe, 21.0%; and, profound, 11.6%. With a prescribed duration of 14 days, subjects wore the device a median (interquartile range [IQR]) of 12.2 days (4.1-14.0); total analysis time was a median of 9.5 days (3.4-13.5). A total of 29 subjects (30.5%) received cardiac diagnoses not previously identified (median = 1 new diagnosis; range: 1-5). CONCLUSIONS: This pilot study suggests the possible utility of an ambulatory monitoring patch device in an adult population with I/DD. Investigators recommend larger studies to confirm such preliminary findings to ultimately improve clinical management and patient quality of life.


Assuntos
Eletrocardiografia Ambulatorial , Cooperação do Paciente , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial , Adesivos , Pessoas com Deficiência , Deficiência Intelectual/complicações
13.
Kardiol Pol ; 82(3): 353-359, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38493471

RESUMO

Implantable loop recorders (ILR) are considered increasingly helpful in diagnosing cardio-neurological conditions, especially if arrhythmic events are of high clinical importance but are unlikely to be captured by standard methods of electrocardiogram recording due to the low frequency of events and short duration of a single event. The compelling evidence from randomized trials and observational studies strongly supports ILR utilization in patients after cryptogenic stroke or transient ischemic attack and in patients with recurrent transient loss of consciousness of unknown origin. These two groups of patients are expected to gain the most from initiating ILR-driven clinically effective management strategies. Stroke or transient ischemic attack survivors with detected subclinical atrial fibrillation can be switched from antiplatelets to anticoagulants, whilst patients with recurrent syncope may avoid severe injuries and/or substantial impairment of their quality of life. This joint opinion of the Heart Rhythm Association of the Polish Cardiac Society and experts from the Polish Neurological Society summarizes the up-to-date rationale for using ILR in everyday clinical practice and describes the road map for implementing this technology in Poland. Special emphasis is placed on the most recent guidelines issued by both cardiological and neurological scientific societies.


Assuntos
Fibrilação Atrial , Ataque Isquêmico Transitório , Humanos , Polônia , Prova Pericial , Qualidade de Vida , Fibrilação Atrial/diagnóstico , Eletrocardiografia Ambulatorial
14.
Ital J Pediatr ; 50(1): 54, 2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38500213

RESUMO

BACKGROUND: There are different findings on heart rate variability (HRV) and pediatric obstructive sleep apnea (pOSA) by an overnight HRV or a 1-hr HRV. However, there is limited data of HRV and pOSA diagnosis by using a 24-h HRV test. This study aimed to evaluate if HRV had potential for OSA diagnosis by using a 24-h HRV test. METHODS: This was a prospective study included children age between 5 and 15 years old, presenting with snoring, underwent polysomnography and a 24-h Holter monitoring. Predictors for pOSA diagnosis were analyzed using logistic regression analysis. RESULTS: During the study period, there were 81 pediatric patients met the study criteria. Of those, 65 patients (80.25%) were diagnosed as OSA. There were three factors were independently associated with OSA: standard deviation of all normal interval (SDNN), high frequency (HF), and low frequency (LF). The adjusted odds ratios of these factors were 0.949 (95% confidence interval 0.913, 0.985), 0.786 (95% confidence interval 0.624, 0.989), and 1.356 (95% confidence interval 1.075, 1.709). CONCLUSIONS: HRV parameters including SDNN, HF, and LF were associated with pOSA diagnosis in children by using the 24-h Holter monitoring.


Assuntos
Apneia Obstrutiva do Sono , Humanos , Criança , Pré-Escolar , Adolescente , Frequência Cardíaca/fisiologia , Estudos Prospectivos , Apneia Obstrutiva do Sono/diagnóstico , Eletrocardiografia Ambulatorial , Polissonografia
15.
Eur Heart J ; 45(14): 1255-1265, 2024 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-38445836

RESUMO

BACKGROUND AND AIMS: Available data on continuous rhythm monitoring by implantable loop recorders (ILRs) in patients with Brugada syndrome (BrS) are scarce. The aim of this multi-centre study was to evaluate the diagnostic yield and clinical implication of a continuous rhythm monitoring strategy by ILRs in a large cohort of BrS patients and to assess the precise arrhythmic cause of syncopal episodes. METHODS: A total of 370 patients with BrS and ILRs (mean age 43.5 ± 15.9, 33.8% female, 74.1% symptomatic) from 18 international centers were included. Patients were followed with continuous rhythm monitoring for a median follow-up of 3 years. RESULTS: During follow-up, an arrhythmic event was recorded in 30.7% of symptomatic patients [18.6% atrial arrhythmias (AAs), 10.2% bradyarrhythmias (BAs), and 7.3% ventricular arrhythmias (VAs)]. In patients with recurrent syncope, the aetiology was arrhythmic in 22.4% (59.3% BAs, 25.0% VAs, and 15.6% AAs). The ILR led to drug therapy initiation in 11.4%, ablation procedure in 10.9%, implantation of a pacemaker in 2.5%, and a cardioverter-defibrillator in 8%. At multivariate analysis, the presence of symptoms [hazard ratio (HR) 2.5, P = .001] and age >50 years (HR 1.7, P = .016) were independent predictors of arrhythmic events, while inducibility of ventricular fibrillation at the electrophysiological study (HR 9.0, P < .001) was a predictor of VAs. CONCLUSIONS: ILR detects arrhythmic events in nearly 30% of symptomatic BrS patients, leading to appropriate therapy in 70% of them. The most commonly detected arrhythmias are AAs and BAs, while VAs are detected only in 7% of cases. Symptom status can be used to guide ILR implantation.


Assuntos
Síndrome de Brugada , Desfibriladores Implantáveis , Marca-Passo Artificial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Arritmias Cardíacas/complicações , Arritmias Cardíacas/diagnóstico , Síndrome de Brugada/complicações , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/terapia , Eletrocardiografia/métodos , Eletrocardiografia Ambulatorial/métodos , Adulto
16.
Medicina (Kaunas) ; 60(2)2024 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-38399629

RESUMO

Background and Objective: In the landscape of heart failure, non-cardiac comorbidities represent a formidable challenge, imparting adverse prognostic implications. Holter ECG monitoring assumes a supplementary role in delineating myocardial susceptibility and autonomic nervous system dynamics. This study aims to explore the potential correlation between Holter ECG parameters and comorbidities in individuals with ischemic cardiomyopathy experiencing heart failure (HF), with a particular focus on the primary utility of these parameters as prognostic indicators. Materials and Methods: In this prospective inquiry, a cohort of 60 individuals diagnosed with heart failure underwent stratification into subgroups based on the presence of comorbidities, including diabetes, chronic kidney disease, obesity, or hyperuricemia. Upon admission, a thorough evaluation of all participants encompassed echocardiography, laboratory panel analysis, and 24 h Holter monitoring. Results: Significant associations were uncovered between diabetes and unconventional physiological indicators, specifically the Triangular index (p = 0.035) and deceleration capacity (p = 0.002). Pertaining to creatinine clearance, notable correlations surfaced with RMSSD (p = 0.026), PNN50 (p = 0.013), and high-frequency power (p = 0.026). An examination of uric acid levels and distinctive Holter ECG patterns unveiled statistical significance, particularly regarding the deceleration capacity (p = 0.045). Nevertheless, in the evaluation of the Body Mass Index, no statistically significant findings emerged concerning Holter ECG parameters. Conclusions: The identified statistical correlations between non-cardiac comorbidities and patterns elucidated in Holter ECG recordings underscore the heightened diagnostic utility of this investigative modality in the comprehensive evaluation of individuals grappling with HF. Furthermore, we underscore the critical importance of the thorough analysis of Holter ECG recordings, particularly with regard to subtle and emerging parameters that may be overlooked or insufficiently acknowledged.


Assuntos
Cardiomiopatias , Diabetes Mellitus , Insuficiência Cardíaca , Isquemia Miocárdica , Humanos , Eletrocardiografia Ambulatorial , Projetos Piloto , Estudos Prospectivos , Isquemia Miocárdica/complicações , Isquemia Miocárdica/diagnóstico , Insuficiência Cardíaca/complicações , Cardiomiopatias/complicações , Cardiomiopatias/diagnóstico , Frequência Cardíaca
17.
Clin Auton Res ; 34(1): 137-142, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38402334

RESUMO

BACKGROUND: Approximately 50% of patients with unexplained syncope and negative head-up tilt test (HUTT) who have an electrocardiogram (ECG) documentation of spontaneous syncope during implantable loop recorder (ILR) show an asystolic pause at the time of the event. OBJECTIVE: The aim of the study was to evaluate the age distribution and clinical predictors of asystolic syncope detected by ILR in patients with unexplained syncope and negative HUTT. METHODS: This research employed a retrospective, single-center study of consecutive patients. The ILR-documented spontaneous syncope was classified according to the International Study on Syncope of Uncertain Etiology (ISSUE) classification. RESULTS: Among 113 patients (54.0 ± 19.6 years; 46% male), 49 had an ECG-documented recurrence of syncope during the observation period and 28 of these later (24.8%, corresponding to 57.1% of the patients with a diagnostic event) had a diagnosis of asystolic syncope at ILR: type 1A was present in 24 (85.7%), type 1B in 1 (3.6%), and type 1C in 3 (10.7%) patients. The age distribution of asystolic syncope was bimodal, with a peak at age < 19 years and a second peak at the age of 60-79 years. At Cox multivariable analysis, syncope without prodromes (OR 3.7; p = 0.0008) and use of beta blockers (OR 3.2; p = 0.002) were independently associated to ILR-detected asystole. CONCLUSIONS: In patients with unexplained syncope and negative HUTT, the age distribution of asystolic syncope detected by ILR is bimodal, suggesting a different mechanism responsible for asystole in both younger and older patients. The absence of prodromes and the use of beta blockers are independent predictors of ILR-detected asystole.


Assuntos
Parada Cardíaca , Síncope , Humanos , Masculino , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Feminino , Estudos Retrospectivos , Distribuição por Idade , Síncope/diagnóstico , Síncope/etiologia , Parada Cardíaca/complicações , Eletrocardiografia , Eletrocardiografia Ambulatorial/efeitos adversos
18.
Arch Cardiovasc Dis ; 117(3): 186-194, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38326152

RESUMO

BACKGROUND: An implantable loop recorder is an effective tool for diagnosing unexplained syncope. However, after a first episode in non-high-risk patients, the usefulness of implantable loop recorder implantation remains unclear. AIMS: To analyse relevant risk factors for significant bradycardia in order to identify patients who do or do not benefit from implantable loop recorder implantation. Also, to study whether implantable loop recorder implantation with remote monitoring is associated with less recurrence of traumatic syncope. METHODS: This was a retrospective monocentric study including patients with implantable loop recorder implantation after unexplained syncope, using remote monitoring and iterative consultations. RESULTS: Two hundred and thirty-seven patients were implanted for unexplained syncope. Significant bradycardia occurred in 53 patients (22.4%): 23 (43.4%) caused by paroxysmal atrioventricular block and 30 (56.6%) caused by sinus node dysfunction, leading to permanent pacemaker implantation in 48 patients. Compared with younger patients, there was a 3.46-fold increase (95% confidence interval 1.92-6.23; P<0.0001) in the risk of significant bradycardia in patients aged≥60 years. Based on multivariable analysis, only "typical syncope" was associated with significant bradycardia occurrence (hazard ratio 3.14, 95% confidence interval 1.75-5.65; P=0.0001). There was no recurrence of significant bradycardia with traumatic complications among patients implanted for traumatic syncope. CONCLUSIONS: This study shows that: (1) implantable loop recorders identify more significant bradycardia in patients aged≥60 presenting with a first non-high-risk typical syncope, suggesting that an implantable loop recorder should be implanted after a first episode of unexplained syncope in such conditions; and (2) after traumatic syncope, implantable loop recorder implantation is safe, and is associated with little or no recurrence of traumatic syncope.


Assuntos
Bradicardia , Síncope , Humanos , Bradicardia/diagnóstico , Bradicardia/terapia , Bradicardia/complicações , Estudos Retrospectivos , Síncope/diagnóstico , Síncope/etiologia , Síncope/terapia , Eletrocardiografia Ambulatorial/efeitos adversos , Medição de Risco , Eletrodos Implantados/efeitos adversos
19.
J Am Heart Assoc ; 13(5): e032890, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38390808

RESUMO

BACKGROUND: Implantable loop recorders (ILRs) are increasingly placed for arrhythmia detection. However, historically, ≈75% of ILR alerts are false positives, requiring significant time and effort for adjudication. The LINQII and LUX-Dx are remotely reprogrammable ILRs with dual-stage algorithms using artificial intelligence to reduce false positives, but their utility in routine clinical practice has not been studied. METHODS AND RESULTS: We identified patients with the LINQII and LUX-Dx who were monitored by the Veterans Affairs National Cardiac Device Surveillance Program between March and June 2022. ILR programming was customized on the basis of implant indication. All alerts and every 90-day scheduled transmissions were manually reviewed. ILRs were remotely reprogrammed, as appropriate, after false-positive alerts or 2 consecutive same-type alerts, unless there was ongoing clinical need for that alert. Outcomes were total number of transmissions and false positives. We performed medical record review to determine if patients experienced any adverse clinical events, including hospitalization and mortality. Among 117 LINQII patients, there were 239 total alerts, 43 (18.0%) of which were false positives. Among 105 LUX-Dx patients, there were 300 total alerts, 115 (38.3%) of which were false positives. LINQIIs were reprogrammed 22 times, resulting in a decrease in median alerts/day from 0.13 to 0.03. LUX-Dx ILRs were reprogrammed 52 times, resulting in a decrease from 0.15 to 0.01 median alerts/day. There were no adverse clinical events that could have been identified by superior or earlier arrhythmia detection. CONCLUSIONS: ILRs with artificial intelligence algorithms and remote reprogramming ability are associated with reduced alert burden because of higher true-positive rates than prior ILRs, without missing potentially consequential arrhythmias.


Assuntos
Arritmias Cardíacas , Inteligência Artificial , Humanos , Arritmias Cardíacas/diagnóstico , Próteses e Implantes , Algoritmos , Diagnóstico Precoce , Eletrocardiografia Ambulatorial/métodos
20.
JACC Clin Electrophysiol ; 10(4): 670-681, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38340116

RESUMO

BACKGROUND: Mitral valve prolapse (MVP) may be associated with ventricular arrhythmias (VA) even in the absence of significant valvular regurgitation. Curling, mitral annulus disjunction (MAD) and myocardial fibrosis (late gadolinium enhancement [LGE]) may account for arrhythmogenesis. OBJECTIVES: This study investigated the determinants of VA in patients with MVP without significant regurgitation. METHODS: This study included 108 patients with MVP (66 female; median age: 48 years) without valve regurgitation. All patients underwent 12-lead electrocardiography, 12-lead 24-hour electrocardiographic Holter monitoring, exercise stress test, and cardiac magnetic resonance. Patients were divided into 2 groups (arrhythmic and no-arrhythmic MVP), according to the presence of VA with a right bundle branch block pattern. RESULTS: The 62 patients (57%) with arrhythmic MVP showed: 1) higher MAD (median length: 6.0 vs 3.2 mm; P = 0.017); 2) higher prevalence of curling (79% vs 52%; P = 0.012); and 3) higher prevalence of left ventricular LGE (79% vs 52%; P = 0.012). Mediation analysis showed that curling had both a direct (P = 0.03) and indirect effect mediated by LGE (P = 0.04) on VA, whereas the association between MAD and VA was completely mediated by LGE. Patients with severe VA showed more pronounced morphofunctional alterations, in terms of MAD (7.0 vs 4.6 mm; P = 0.004) and presence and severity of curling (respectively, 91% vs 64%; P = 0.010; and 4 vs 3 mm; P = 0.004), compared to those without severe VA. CONCLUSIONS: In patients with MVP the occurrence of VA with right bundle branch block morphology is the expression of more severe morphologic, mechanical, and tissue alterations. Curling has both a direct and an indirect effect on VA.


Assuntos
Arritmias Cardíacas , Prolapso da Valva Mitral , Humanos , Feminino , Pessoa de Meia-Idade , Prolapso da Valva Mitral/fisiopatologia , Prolapso da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/complicações , Masculino , Adulto , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/epidemiologia , Eletrocardiografia , Imageamento por Ressonância Magnética , Eletrocardiografia Ambulatorial , Teste de Esforço , Idoso
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...